Shijiazhuang An Pump Machinery Co., Ltd.
Shijiazhuang An Pump Machinery Co., Ltd.
Horizontal multistage centrifugal condensate pump for air conditioner
  • Horizontal multistage centrifugal condensate pump for air conditioner
  • Horizontal multistage centrifugal condensate pump for air conditioner
  • Horizontal multistage centrifugal condensate pump for air conditioner
  • Horizontal multistage centrifugal condensate pump for air conditioner
  • Horizontal multistage centrifugal condensate pump for air conditioner
  • Horizontal multistage centrifugal condensate pump for air conditioner
Horizontal multistage centrifugal condensate pump for air conditioner
Horizontal multistage centrifugal condensate pump for air conditioner
Horizontal multistage centrifugal condensate pump for air conditioner
Horizontal multistage centrifugal condensate pump for air conditioner
Horizontal multistage centrifugal condensate pump for air conditioner
Horizontal multistage centrifugal condensate pump for air conditioner

Horizontal multistage centrifugal condensate pump for air conditioner

Delivery Time:
10 Days
Quantity:

Your message must be between 20 to 2000 characters

Contact Now
Basic Info
Basic Info
Place of Origin: Hebei, China (Mainland)
Product Description
Product Description
Horizontal multistage centrifugal condensate pump for air conditioner     Product Description Horizontal multistage centrifugal condensate pump for air conditioner introduction Multi-stage section centrifugal pump, the excellent hydraulic models are high-efficiency, energy-saving, and have wide performance range, operating safety & steady, low noise, long life and installing & repairing is very convenient etc. It can deliver heat water, oil, corrosive or wear albe medium by changing the material, seal or adding cooling system.   Horizontal multistage centrifugal condensate pump for air conditioner detailed specification       Features:  
1) Compact and reasonable structure
2) Shaft seal can be mechanical seal or packing seal
3) Advanced hydraulic model to feature high efficiency and little energy consumption

Working conditions:  
1) Flow: 5~450³/h
2) Head: 50~600m
3) Max. system pressure: 3MPa
4) Medium temperature: -15°C~120°C
5) Motor: IP44, IP54
6) Insulation: class B, class F       Horizontal multistage centrifugal condensate pump for air conditioner parameter  

QD(G) Series multistage pump data

Pump Type

Flow

Head

Power

(m3/h)

(m)

(KW)

QD(G) 6-25

3-7.5

73.5-306

4-11

QD(G) 12-25

7.5-15

69-338.4

5.5-22

QD(G) 12-50

7.5-15

139.5-648

18.5-75

QD(G) 25-30

15-30

82.5-340

15-45

QD(G) 25-50

15-30

15.78-618

22-110

QD(G) 46-30

30-55

81-340

22-75

QD(G) 46-50

30-55

138-666

37-132

QD(G) 85-45

55-100

78-459

37-160

QD(G) 85-67

55-100

183-666

90-250

QD(G) 155-67

100-185

177-684

132-400

QD(G) 280-43

185-335

114-423

160-450

QD(G)280-65

185-355

372-680

500-800

QD(G)450-60

335-684

171-650

360-3400

 
Horizontal multistage centrifugal condensate pump for air conditioner structure     For this series horizontal multistage centrifugal pump, both ends of it are supported, the casing portion is in a sectional form. it is connected to and actuated by a motor via a resilient clutch and the rotating direction of it. viewing from the actuating end. is clockwise. Refer to Fig. I for the structure of it.

Stator portion
Consists of suck-in section. middle-section, spitting section, guide vane, packing etc., which are linked together with a take-up bolt. with both suck-in and spitting mouths vertically upward.

Rotor portion
Consists of a shaft, impeller, balancing disk, muff etc. Parts.

Bearing portion
The whole rotor is supported by the roller bearings or
sliding bearings on both ends of the shaft and the bearings are lubricated with grease or 20# engin oil.

Cooling and seal of pump
The joint-part between suction section, intermediate section and discharge section with be coated with molybdenum disulfide lubricating grease as seal. Rotor and fixed parts will be sealed by seal ring, guide-vane jacket and packing. The packing tensile degree of shaft seal should be proper and seep should be feasible dip by dip Unload run should be forbid. The seal ring and guide vane jacket should be replaced if they are too worn to be used any more and even do harm to pump work. There is spare shaft sleeve near shaft seal to protect shaft of pump.   Pump Application: Horizontal multistage centrifugal condensate pump for air conditioner application 1) Water supply and discharge in high-rise buildings
2) Fire water supply in constructions
3) Water supply and discharge in factories and mines
4) Long distance delivery
5) Cyclic pressurization in production   Packaging & Shipping Horizontal multistage centrifugal condensate pump for air conditioner packing and shipping       Our Services Our Services   1. Offer Large capacity pump solutions
2. Selection
3. OEM available
4. ODM available
5. Design
6. Installation
7. Maintenance   Company Information Our Main Products Some clients visit our factory   Contact Us Learn more , please contact us directly.   Mandy Wang
International Dept. Shijiazhuang An pump Machinery Co.,Ltd Web:www.angroupcn.com Email:coco(@)angroupcn.com Tel:86-311-89940549    Fax:86-311-86271170 WhatsApp:0086-137-3107-1183 Skype:mandy.anpump    

Send your message to this supplier

  • Mr. David An

  • Enter between 20 to 4,000 characters.