cable clamp dead end grip for adss cable
Quantity:
Your message must be between 20 to 2000 characters
Contact NowBasic Info
Basic Info
Place of Origin: | Hebei, China (Mainland) |
---|
Product Description
Product Description
Specifications cable clamp dead end grip for adss cable,dead end grip
Al clad steel
tensile strength 95%RTS
strength:70,100,120KN
ISO
cable clamp dead end grip for adss cable,dead end grip
Composition: inner pre-twisted wire, the outer pre-twisted wire, thimble, PD-type peg board, U-type hanging ring. Purposes: to bear the whole tension of the optical fiber composite overhead ground wire (OPGW) on the tower connected to the resistance to Zhang. Features: a. uniform stress distribution, no stress concentration points, can well protect fiber optic cable.
b. In the lateral compressive strength of not more than fiber optic cable under the premise of the fiber optic cable have greater holding power, able to withstand greater tension.
c. The holding force of the fiber optic cable fiber optic cable rated tensile strength of not less than (RTS) 95%, while not damage OPGW cable.
d. high-quality aluminum-clad material, to improve the mechanical properties of the clamp and corrosion resistance. Technical requirements: meet the DL / T 766-2003 optical fiber composite overhead ground wire (OPGW) with the pre-cutter-style fittings technical requirements and test methods. Ordering Information:
a. According to OPGW cable rated tensile strength and diameter to select the appropriate Clamp.
b. the number of configurations: one set / Terminal Tower (including gantry); 2 sets / Tension tower.
c. The inner clamp pre-twisted wire with OPGW outer spiral twist to the contrary, the standard configuration in accordance with OPGW outer stranding to the right-hand, such as a L, should be specified in the order contract.
d. The clamp to withstand a full tension, it was proposed one-time use.
e. provide the first tower to connect only with a gold pattern.
f. Clamp intensity is divided into 70kN, 100kN, 120kN and so on.
OPGW Stranding with pre-Clamp Specification Model Parameter table:
Drawing:
Product:
Component:
Package:
Delivery:
Construction site:
Test Equipment:
ISO:
Al clad steel
tensile strength 95%RTS
strength:70,100,120KN
ISO
cable clamp dead end grip for adss cable,dead end grip
Composition: inner pre-twisted wire, the outer pre-twisted wire, thimble, PD-type peg board, U-type hanging ring. Purposes: to bear the whole tension of the optical fiber composite overhead ground wire (OPGW) on the tower connected to the resistance to Zhang. Features: a. uniform stress distribution, no stress concentration points, can well protect fiber optic cable.
b. In the lateral compressive strength of not more than fiber optic cable under the premise of the fiber optic cable have greater holding power, able to withstand greater tension.
c. The holding force of the fiber optic cable fiber optic cable rated tensile strength of not less than (RTS) 95%, while not damage OPGW cable.
d. high-quality aluminum-clad material, to improve the mechanical properties of the clamp and corrosion resistance. Technical requirements: meet the DL / T 766-2003 optical fiber composite overhead ground wire (OPGW) with the pre-cutter-style fittings technical requirements and test methods. Ordering Information:
a. According to OPGW cable rated tensile strength and diameter to select the appropriate Clamp.
b. the number of configurations: one set / Terminal Tower (including gantry); 2 sets / Tension tower.
c. The inner clamp pre-twisted wire with OPGW outer spiral twist to the contrary, the standard configuration in accordance with OPGW outer stranding to the right-hand, such as a L, should be specified in the order contract.
d. The clamp to withstand a full tension, it was proposed one-time use.
e. provide the first tower to connect only with a gold pattern.
f. Clamp intensity is divided into 70kN, 100kN, 120kN and so on.
OPGW Stranding with pre-Clamp Specification Model Parameter table:
Model | Scope | The scope of the inner twisted wire | Outer twist wire | |||||||
Minimum diameter(mm) | Maximum diameter(mm) | The length of twisted wire | The composition of root number | Single-wire diameter(mm) | Weight(kg) | The length of twisted wire | The composition of root number | Single-wire diameter mm | Mass(kg) | |
ONZ-0940/60 | 9.0 | 9.4 | 1450 | 12 | 2.5 | 0.59 | 950 | 7 | 3.0 | 0.67 |
ONZ-0990/60 | 9.5 | 9.9 | 1450 | 13 | 2.5 | 0.64 | 950 | 7 | 3.0 | 0.67 |
ONZ-1040/80 | 10.0 | 10.4 | 1550 | 13 | 2.5 | 0.69 | 1050 | 7 | 3.5 | 1.01 |
ONZ-1090/80 | 10.5 | 10.9 | 1550 | 14 | 2.5 | 0.74 | 1050 | 7 | 3.5 | 1.01 |
ONZ-1150/80 | 11.0 | 11.5 | 1550 | 14 | 2.5 | 0.74 | 1050 | 7 | 3.5 | 1.01 |
ONZ-1190/100 | 11.6 | 11.9 | 1600 | 15 | 2.5 | 0.82 | 1100 | 8 | 3.5 | 1.21 |
ONZ-1240/100 | 12.0 | 12.4 | 1600 | 16 | 2.5 | 0.87 | 1100 | 8 | 3.5 | 1.21 |
ONZ-1290/100 | 12.5 | 12.9 | 1600 | 16 | 2.5 | 0.87 | 1100 | 8 | 3.5 | 1.21 |
ONZ-1340/100 | 13.0 | 13.4 | 1700 | 16 | 2.5 | 0.92 | 1200 | 7 | 4.0 | 1.50 |