Digital Radiography system dr machine/ X Ray machine DR unit
- Delivery Time:
- 20 Days
Quantity:
Your message must be between 20 to 2000 characters
Contact NowBasic Info
Basic Info
Place of Origin: | Hebei, China (Mainland) |
---|
Product Description
Product Description
Digital Radiography system dr machine/ X Ray machine DR unit 1. Characteristics: (1) Accurate medical machine (2) Rapid x-ray machine (3) Intelligent x ray imaging machine (4) Powerful image system 2. Main Features: (1) Stable performance (2) Low exposure dose (3) High-quality images (4) Multi-functional photography system (5) Standardized PACS system can be adapted to the needs of the new network era. 3. Specifications (1) With high precision high voltage output. Stable X-Ray is possible even with fluctant power supply. (2) High precision control of photography time (3) High precision control of tube current and with AEC function. (4) Mutiple radiography condition set mode. (5) Self-diagnosis and Self-protection (6) Small in size and Low weight, easy to install. (7) Meet your requirement of different clinical examination.
DR5000XI 1. Characteristics: (1) Accurate medical machine (2) Rapid x-ray machine (3) Intelligent x ray imaging machine (4) Powerful image system 2. Main Features: (1) Stable performance (2) Low exposure dose (3) High-quality images (4) Multi-functional photography system (5) Standardized PACS system can be adapted to the needs of the new network era. 3. Specifications (1) With high precision high voltage output. Stable X-Ray is possible even with fluctant power supply. (2) High precision control of photography time (3) High precision control of tube current and with AEC function. (4) Mutiple radiography condition set mode. (5) Self-diagnosis and Self-protection (6) Small in size and Low weight, easy to install. (7) Meet your requirement of different clinical examination. 4. Parameters:
5. Exhibition Show:
6. Welcome to talk with us to know more detail information: Skype: liulijiecn
DR5000XI 1. Characteristics: (1) Accurate medical machine (2) Rapid x-ray machine (3) Intelligent x ray imaging machine (4) Powerful image system 2. Main Features: (1) Stable performance (2) Low exposure dose (3) High-quality images (4) Multi-functional photography system (5) Standardized PACS system can be adapted to the needs of the new network era. 3. Specifications (1) With high precision high voltage output. Stable X-Ray is possible even with fluctant power supply. (2) High precision control of photography time (3) High precision control of tube current and with AEC function. (4) Mutiple radiography condition set mode. (5) Self-diagnosis and Self-protection (6) Small in size and Low weight, easy to install. (7) Meet your requirement of different clinical examination. 4. Parameters:
Item | Main Parameter |
1. X-RAY High Frequency High Voltage Generator | |
1.1 Power Voltage | Three Phases 380V±38V |
1.2 Max Output Power | 50kW |
1.3 Tube Current (mA) | 10mA~630mA |
1.4 Tube Voltage (kV) | 40kV~150kV |
1.5 Exposure time | 1ms~6300ms |
2. X-RAY tube | |
2.1 Max tube voltage | 150kV |
2.2 Focus | 0.6mm/1.2mm |
2.3 Target Angle | 12° |
3. Digital Flat Panel Detector | |
3.1 Imaging Material | Amorphous silicon/cesium iodide |
3.2 Power Requirement | AC220-240V,50/60Hz,1.75A |
3.3 Detector Size | 17×17 inch |
3.4 Spatial resolution | No less than 3.6lp/mm |
3.5 Installation | Fixed setting |
4. DR Frame | |
4.1 Frame | UC-Arm(new) |
4.2 Function | Vertical and clinostatism |
4.3 SID | 1000mm~1800mm |
4.4 Installation | Fixed on ground |
4.5 Power | AC220V |
5. Mobile Photography bed | |
5.1 Bed Size | L×W×H=2020mm×630mm×530mm |
5.2 Operation | Manual |
6. Image Acquisition Workstation | |
6.1 CPU | ≥2.8GHz |
6.2 Internal Storage | ≥2GB |
6.3 Disk Size | ≥320GB |
6.4 Display | LCD |
6.5 System | windows |
6.6 Connector | DICOM3.0 |
7.Image Processing Software | |
7.1 Possible to acquire image, Adjust the size, light, contrast, rotation,overturn of Image. | |
7.2 Possible to transmit image with Dicom3.0, and with function of inquire, edit and print. | |
7.3 With function of management the information of patients and image. |